Problem |
Solution |
Provide maintenance-free, completely drainable, MST strike tank transfer pumps (3) for nuclear waste clean-up application Caustic waste solution (salt slurry) with 0.07% by weight solids, 1.3 SG, 95° F, 10-14 pH, Radioactive ambient* Duty: 120 GPM @63ft. Total Head *Top of tank (Affects Motor): Gamma Center of tank (Affects Pump): Alpha & Beta |
|
Model: 6000 VEP-2 (A20) Commercial vertical centrifugal sump pump with submerged product lubricated sleeve bearing (1) fabricated from SRS-specified materials Suction: 2-1/2" FF Flange (150#) Discharge: (1-1/2") 2" Non-fitted at the m.p. (23.75 x 31.38 x 3/4" Thick type 316 S/S) |
|
Features |
|
|
|
Problem
|
Solution
|
Naval
wastewater treatment facility required special cantilever vertical sump
pump for transfer of waste water with traces of notroglycerine, 20GPM
@ 43 FT TH. |
|
Model:
5000 VEC-3
Material: 316 Stainless Steel Size: 1.5" FF FL Discharge at mounting plate |
|
Features
|
|
|
|
|
|
Problem
|
Solution
|
Pumping chemical fill line for waste water treatment system consisting of 98% H 2SO 4and 10FeCl 3at 120°F. | |
Model:
4000 VE-1
Material: Hastelloy B-2; Extension: 44" below Mounting Plate Size: 1.5" Non-fitted x 1" FNPT at Housing Motor: Delco 7EH, 1.5 HP, 1750 RPM |
|
Features
|
|
|
|
Problem
|
Solution
|
Vertical pump for Molten Salts at 900°F; no submerged bearings allowed; 200 GPM at 12 FT TH. |
|
Model:
4000 VEC-HDI
Vertical, Cantilever Shaft Centrifugal Pump Material: Mild Steel Size: 4 x 4 FL (150#) - 17 |
|
Features
|
|
|
|
Problem
|
Solution
|
|
|
Model: 3000VEC-1-Vor |
|
Features
|
|
|
|
Problem
|
Solution
|
Squeeze
a duplex vertical Sump Pump through a 19-1/2" diameter opening in
a 10 FT deep tank: Aluminum products manufacturer's rigid container sheet
plant required 20 GPM @ 25 FT TH (At the impeller) of 96% H 2SO 4, 1.86
SG, Ambient P.T. |
|
Model:
3000VE-1 (AA)
Duplex Vertical Sump Pump Size: 1.5" FF FL (150#) at the mounting plates (22" Dia. Semi-Circle x 1/2" 316 Stainless Steel) |
|
Features
|
|
|
|
|
|
Problem
|
Solution
|
Aircraft manufacturer required low maintenance vertical sump pump for parts cleaning washdown removal to 100°F, subject to exposure to dilute NaOH, HNO 3, HCl, H 2SO 4, H 2CrO 4and HF; 20 GPM @ 60 FT TH. | |
Model:
2000VEC-1
Duplex Vertical Cantilever Material: 316 Stainless Steel Fitted CPVC Size: (Suction) 1.5" FNPT w/11" Tailpipe (Discharge) 1" FF FL (150#) at M.P. |
|
Features
|
|
|
|
Problem
|
Solution
|
The pumping of various "Fluorides" required a vertical inline centrifugal pump using Hastelloy C-22 as the material of construction. |
|
Model:
3000DVL-H
Vertical Inline, Double Sealed, Centrifugal Booster Pump. Material: Hastelloy C-22 |
|
Features
|
|
|
|
Problem
|
Solution
|
Manufacturer of specialty chemicals mandated by EPA to install pumping system for containment of runoff, filter backwash exchangers and possible chemical spills: 200 GPM @ 46 Ft. TH, dilute quantities of HCI, NaOH and various solvents. |
|
Model:
5000 DVL-VEC
Vertical In-Line, Cantilever Shaft |
|
Features
|
|
|
|
Problem
|
Solution
|
In nearly inaccessible area with dripping, fuming NHO 3atmosphere, pump concentrated NHO 3(1.6 specific gravity) 5 GPM @ 110 FT TH. Pump to be capable of running dry (no process solution flowing) for minimum of 2 hours with no leakage or damage. | |
Model:
3000 DVL-H
Double-Sealed In-Line Vertical All pump parts, fasteners and exposed motor parts 316 Stainless Steel. Total weight of pump and motor assembly did not exceed 65 lbs. |
|
Features
|
|
|
|
|
|